Data Acquisition

Storm

System 5000™

H-500XL

Data Acquisition with
Satellite Communications

H-522+™

H-522

H-5223

Data Acquisition with
Pressure Measurement

H-350XL

Satellite Transmitters

H-2221

Radio Transmitters

H-424-MS

H-4400

H-4401-M/S & H-4410 M/S

Data & Voice Modems

H-2191/H-2192

Submersible Sensors

H-3123

H-310

Non-Submersible Sensors

H-3551 "Smart Gas" Bubbler

H-3531 "FlashLite" Pressure

H-3553 Bubbler & Pressure

H-3521 Pressure Sensor

Non-Contact Sensors

H-3611 / H-3612 / H-3613

Position Indicators

H-335

H-336

Alert Modules

H-264

Shaft Encoders

H-3301 / H-3311 / H-3342

Met Sensors

H-340 Rain Gauge

H-340SDI Rain Gauge

H-375 Wind Sensor

H-377 Air/Water/Soil Temp

H-378 Barometric Sensor

H-380 Relative Humidity

H-3791 Pyranometer

Other YSI Products

YSI Water Quality Instruments

SonTek Acoustic Doppler Systems for water velocity

YSI Systems & Services

Ask a Question

Downloads

Events & Training

Find a Distributor

Product Service

Resource Library

Warranty Card Online

Welcome from the GM

History

Blog

Career Opportunities

Environmental Stewardship

Sustainability Report

Quality

Xylem Watermark

WaterLog - a xylem brand
Find WaterLOG on Facebook Watch WaterLOG on YouTube
Loading

H-264 ALERT Serial Interface

Share |

The WaterLOG® H-264 ALERT Serial Interface (ASI) is a multi-purpose device that accepts ALERT ID and data reports in variety of serial data formats. It buffers, parses, and converts them to 300 baud FSK audio signals in binary ALERT format. The device controls power, audio and PTT lines of an attached transmitter to send a standard ALERT binary format transmission.

H-264 ALERT Serial Interface

Send me a Quote!
Find a Distributor

Find a Distributor

DAA has Authorized Distributors all over the globe. View a map and find your closest contact for DAA H-264 ALERT Serial Interface products and accessories.


Contact Technical Support

Get Support

Have a question about your H-264 ALERT Serial Interface? Check out the support page with resources compiled just for you.


Product Service

Product Service Centers

Want to return a product for service? Here you'll find authorized service centers and instructions on how to send in your H-264 ALERT Serial Interface.

  • User selectable, flexible serial input:
    •  Asynchronous or Synchronous, True RS-232 level input & output or Logic Levels, and ASCII or Binary ALERT format.
  • Automatic conversion from ASCII ALERT format input to binary ALERT transmission.
  • Double buffered serial interface: receive serial data concurrently with ALERT transmissions.
  • Each buffer accepts up to 10 serial input ALERT messages for conversion and transmission in a single ALERT transmission.
  • High accuracy battery voltage monitor maximizes transmissions available from a battery.
  • User selectable ALERT transmission preamble length (from 101 to 665 milliseconds) allows system design for maximum channel capacity with and without a repeater.
  • Robust ESD and over-voltage protection on serial and battery supply inputs enhances reliability.
  • Hardware watchdog timer guards against excessive transmitter on.
  • 12-second duty cycle timer protects transmitter and ensure no single unit saturates a channel

 

 

 

Data Input

ALERT Asynchronous Serial Input

 

 

 

RS-232 Level

(negative logic) 2 wire input (Data & Gnd)

Logic Level

 (positive logic, 0 – 2.8V min to 16V max), 2 wire input (Data & Gnd)

 Baud Rate

 DIP switch selectable: 300, 1200 or 4800

Asynchronous Format

  data bits, no parity bit, 1 stop bit.

ALERT Synchronous Serial Input

Input Message Format

 SCII ALERT format (8 bytes for each ID+Data message)

Binary ALERT Format

 (4 bytes for each ID+Data message).

 ESD Protection

 +/- 15kV - Human Body Model; +/- 8kV – IEC1000-4-2, Contact Discharge; +/- 15kV – IEC 1000-4-2, Air Gap Discharge.

 

ALERT Synchronous Serial Input

 

 3 Wire Interface

 Sync Data, Sync CLK and Gnd

Logic Level Input

positive logic, 0 – 2.8V min to 16V max)

 Bits Read

Read at positive transitions of Sync CLK line.

 Minimum Positive & Negative CLK pulse width 1 millisecond each (500 Hz data rate, software limited; hardware deglitch filter time constant 200 microseconds).

 EDS Protection

Exceeds JESD 22: 2000-V Human Body Model (A114-A); 200-V Machine Model (A115-A); 1000-V Charged Device Model (C101).

Test Switch Input (forces test transmission) 

 

Contact Closure

2 wire input switch interface; transmission on contact “break”

Open Time Minimum open time 2 milliseconds; RC & Schmitt trigger debounced.

Over-Voltage Protection

100 ohm + 10V bidirectional 400 mW zener diode

EDS Protection

Exceeds JESD 22: 2000-V Human Body Model (A114-A); 200-V Machine Model (A115-A); 1000-V Charged Device Model (C101).

    
Data Output

ALERT Transmitter Interface

 

 

 

4 Wire Interface

Switched Battery Power, Gnd, Push To Talk, and Audio)

Switched Battery Power

Low dropout high side power switch: typically < 0.05 V drop (1 A), max TBD.

High current rating: min 2 A at 18 V continuous without additional heat sink.

High breakdown voltage rating: 30 V.

PTT Output

Open collector NPN output, no pull up; on (“current sink) for “Push to Talk”.

200 mA max current; V(CE) typically 0.3 V at 50 mA.

Audio Tone Output

 AC coupled (non-polarized 1 uF capacitive coupling).

 

200 mV RMS, +/- TBD%; (factory settable for 50 - 707 mV RMS).

 

FSK tones: Mark - 2140 Hz, Space - 1920 Hz, +/- 0.05%.

 

3 pole low pass FSK filter: typical: 3rd harmonics attenuated 30 dB, min TBD

 

No spurious transitions at bit period transitions

 

All Outputs RF attenuated for noise control (in line ferrite bead, nominal 100 ohms series resistance at 100 MHz – 500 MHz).

Transmission Indicators

Green LED on Switched Battery Power output

 

Red LED on “Push to Talk” output.

    
Power Requrements

Input Voltage Range (ASI only) 

 Minimum

4 V DC

 

 Maximum

20 V DC

Supply Current (ASI only, with nominal 12 V DC input):

Idle (waiting for serial input)

Typical:  9 uA Maximum:     TDB

 

Buffer Message Conversion

Typical:  320 uA Maximum:     TBD

 

High speed processing (ADC)

Typical:   2.8 mA Maximum:     TBD

 

ALERT transmission (with LEDs & audio filter on)      

Typical:   10 mA            Maximum:     TBD
    
Mechanical

General

 Size

10.0 cm x 6.20 cm

Mounting Holes

4, (0.381 cm diameter, designed for M3x0.5mm mounting screw clearance)

 

2 located 0.40 cm from top edge and 0.40 cm from the right side

 

2 located 0.40 cm from bottom edge and 2.00 cm from the left side

Connectors

Screw terminal connector rated 125 V DC, 6 A, wire size AWG 28-16, 3.5 mm spacing, and 5.5 mm wire strip length

 

2 pin battery input (left edge),

 

4 pin transmitter I/O (left edge),

 

4 pin serial input (right edge)

 

0.025” gold plate square post, 0.1” on centers; rated 500 V DC, 2.5 A

 

2 pin test switch input header (right edge)

 

4 pin AuxRS232 header (right edge)

 Reset Switch

Momentary, 6.5mm x 6.5 mm, tactile switch
Environmental

Temperature

Operating Temperature -40° to +85° C
Relative Humidity 10% to 95% non-condensing

Miscellaneous
Warranty

The WaterLOG® H-264 is warranted against defects in materials and workmanship for two years from date of shipment.

Specifications subject to change without prior notice due to ongoing commitment to product testing and improvement. LR  February 15, 2011. D49 0211.

 

 

 

 

 